Product categories

Shop Consumables

Instruments, Accys & Service Products

Aluminum 6.7mm Sample Pan | Alternative Product for TA P/N 900786.901

$105.00

Alternative to TA P/N: 900786.901

Comparable to TA P/N: 900760.901
Thermal Support P/N: 5416717.2
Price: $105.00
USA Product

“Press to Fit” with TS P/N: 5316500.2

(BEFORE PURCHASE See More Info)

SKU: 5416717.2 Categories: ,

Description

BEFORE PURCHASE:

  • This product is NOT A DIRECT REPLACEMENT for the TA 900786.901 pan – it is a larger volume alternative. Our 5416717.2 pan is closer to TA “Classic” pan P/N: 900760.901. *Due to the larger volume and slight diameter difference, this pan was not designed to work perfectly in the TA sample press. Many customers do use these in the TA press but these were designed as “Press to Fit” when paired with Thermal Support’s P/N 5316500.2 pan style cover.

___________________________

“Press to Fit” Product 

Aluminum 6.7mm Sample Pan with Deeper 1.7mm Side Wall

Offering as an Alternative to TA Instruments P/N: 900786.901 and Comparable to P/N: 900760.901, Aluminum Standard 6.7mm Sample Pan, Qty. 200

6.7mm size and a 1.7mm wall height, we made these approximately 30% larger, with tight tolerances, as a “Press to Fit” alternative to the original TA pan. When used with a cover, simply press fit the cover (P/N 5316500.2) and it will form around the sample.

“Press to Fit” Encapsulating Instructions

Each sample pan and cover has an operating range of -170° to 600 °C, a volume (µL) 40 and an ambient max pressure. These can be used with nonvolatile solid samples, such as plastics and polymers, and are routinely used for applications such as polymer melting, crystallization, glass transitions of polymers, thermoplastics, and thermosets.

Clean for DSC Product

We manufacture our own products in the USA and as the original manufacturer we are directly involved in the lubricants used in the manufacturing process, the solvent and method used in cleaning our products. After having all new products successfully passing independent testing for several years, we now do high speed DSC runs (greater sensitivity) on all new incoming Lots. Be sure to read our product warranty policy.

——-

In deference to the Original Manufacturers

“Thermal Support LLC is not affiliated with TA Instruments or Waters Corporation. Any claims of compatibility with TA Instruments’ products are the sole claim of Thermal Support and have not been reviewed, approved, or endorsed by Waters Corp. or TA Instruments”

Additional information

Weight .325 lbs
Dimensions 4 × .75 × 3 in
Manufacturer

Thermal Support